Data Center – Fiber polish and types of cable connectors
Data Center
Fiber polish and types of cable connectors
▪︎Fiber polish
Fiber polish refers to the finishing process applied to the end faces of optical fibers after they are cut. The goal of polishing is to achieve a smooth and flat surface on the fiber’s end, minimizing reflections & losses in the transmission of light signals.
》Flat Polish
PC (Physical Contact)
UPC (Ultra Physical Contact)
In this type, the fiber ends are polished to be flat and in physical contact with each other when mated. PC connectors are widely used in telecom. & data applications.
》Angled Polish
APC (Angled_Physical_Contact)
The end faces of the fibers are polished at an angle, usually around 8 degrees. This design reduces back reflections, making APC connectors suitable for applications where low reflection is critical, such as in fiber-to-the-home (FTTH) networks.
▪︎Fiber optic cable connectors
Fiber optic connectors are used to terminate the end of an optical fiber, enabling it to be connected to another fiber or to an active device.
Some common fiber optic cable connectors include:
》SC (Subscriber Connector)
Commonly used in data & telecom applications.
Easy to snap in and out, with a push-pull mechanism. Suitable for high-density installations.
Introduced by: NTT (Nippon Telegraph and Telephone Corporation)
》LC (Lucent Connector)
Widely used in data centers & high-density environments.
Small form factor, similar to SC but half the size. Offers easy installation and high performance.
Introduced by Lucent Technologies (now part of Nokia)
》ST (Straight Tip)
Originally developed by AT&T, widely used in networking & telecom.
Bayonet-style coupling, durable design. Common in older installations.
Introduced by AT&T, it was one of the first fiber optic connectors.
》FC (Fiber Channel)
Commonly used in data storage applications.
Screw-type locking mechanism for secure connections. Suitable for single-mode fibers.
》MTP and MPO (Multiple-Fiber Push-On/Pull-off)
Designed for high-density connections, often used in data centers.
Array of fibers in a single connector, allowing quick connections for multiple fibers simultaneously.
Introduced by: USConec and Corning.
》MT_RJ (Mechanical Transfer-Registered Jack)
Suitable for duplex connectors in networking applications.
Small form factor, integrating two fibers into a single connector. Common in high-density environments.
Introduced By: American National Standards Institute (ANSI) standard.
》SC/APC and LC/APC (Angled Physical Contact)
Applications where low back reflection is critical, such as in fiber-to-the-home (FTTH) networks.
Angled polish on the fiber end to reduce back reflection & improve signal quality in single-mode fibers.
In summary the choice of connector depends on the specific needs of the network, including factors like space constraints, required performance, & the type of optical fiber being used (single-mode or multi-mode).